T 2000: Two-to-One Step-Down, Up to 200W Audio Power

T 2000 Transformer

The T2000 Audio-Bandwidth Conducted Susceptibility Transformer was designed to meet or exceed the LF conducted susceptibility test requirements of DO 160 Section 18. The T2000 is used to apply the required test signals to the lines under test for ripple voltage tests and continuous or transient conducted immunity tests. It may also be used as a 2-to-1 step-down transformer. The secondary can support up to 40AP.

The T2000 transformer supports up to 200W and is able to pass up to 40AP on the secondary. The turns ratio provides a 2-to-1 step down.

The T2000 provides convenient input connectors via binding posts. Standard 0.75-inch spacing of binding posts allows use of standard plugs. Output is via Multi Contact 125A plugs.

A thermal breaker protects the unit against over-current conditions on the primary. A 35 ARMS breaker protects the unit against over-current conditions on the secondary. A rugged, impact-resistant case and robust design protects the transformer from accidental damage.

The T2000 transformer is for use by experienced staff.

T 2000

Low-Frequency Conducted Susceptibility Transformer

  • For testing to DO 160 Section 16 and 18 standard
  • Optimized for use with AE Techron 7220 Series amplifiers
  • Protected from over-current by a thermal breaker on the primary and a 35 ARMS breaker on the secondary
  • Durable steel and high-density polyethylene case for impact resistance

Key Performance Capabilities:

  • Frequency response: 10 Hz to 250 kHz
  • Up to 200W audio power
  • Up to 40 Ap AC or DC secondary current
  • Two-to-one step-down
  • Output via feed-through terminal block connectors (76A); accepts up to AWG 6 wire

Performance

T 2000 Maximum SOA (Safe Operating Area)

T 2000 Safe Operating Area

Specifications

Technical

Transformer DC Resistance:
   Primary: 0.076 ohms
   Secondary: 0.021 ohms
Frequency Response: 10 Hz to 250 kHz
Audio Power: 200W MAX
Dielectric Test: 1500 VDC primary to secondary
Turns Ratio: Two-to-one step down
Secondary Inductance: Approximately 0.6 mH (unloaded)
Protection: Input power-protected via thermal breaker; secondary winding protected via 35ARMS breaker

Controls and Connectors

Input Terminals: 4-way binding posts
Output Terminals: feed-through terminal block connectors (76A); accepts up to AWG 6 wire
Circuit Breaker: Secondary winding limited to 35 ARMS via circuit breaker; push to reset

Physical Characteristics

Case: Steel interior shell with a durable external shell made from high-density polyethylene for impact resistance.
Operating Conditions,
   Temperature:
10°C to 40°C (50°F to 104°F)
   Humidity: 70% or less, non-condensing
Recommended Ambient Temperature: 27°C (77°F)
Cooling: Natural air convection
Weight: 15 lbs. (6.8 kg)
Dimensions (WxDxH): 5.25 in. x 10.375 in. x 9.75 in. (13.3 cm x 26.4 cm x 24.8 cm)

Application

DO 160 Section 18 Testing

T 2000 Application

Standards

Meets or exceeds the performance requirements for testing to these Specifications:

  • Chrysler CS-11809 (2009)
  • DaimlerChrysler DC-1061
  • DO 160 Section 16
  • DO 160 Section 18
  • Ford FMC 1278
  • GLloyd Vl-7-2
  • ISO 11452-10
  • EMC-CS-2010JLR V1.1 (2011-01)
  • MIL STD 461 D CS 101
  • MIL STD 461 D CS 109
  • MIL STD 461 E CS 101
  • MIL STD 461 E CS 109
  • MIL STD 461 F CS 101
  • MIL STD 461 F CS 109
  • MIL-STD-704
  • Mitsubishi ES-X82115
  • SAE J1113-2
  • Tata TST/TS/WI/257

Front & Back

T 2000 front and back

Downloads

T 2000 Datasheet

T 2000 Datasheet

Complete technical specifications

T 2000 Instruction Sheet

T 2000 Instruction Sheet

Includes full specifications plus setup and maintenance instructions

T 2000 Declaration of Conformity

T 2000 Declaration of Conformity

For EU countries

You might also be interested in:

Recommended Products

7224

7224

DC-enabled AC Amplifier

AC Power at 20 kHz: 900 Wrms
For High-Power Applications to: 100 kHz

7234

7234

DC-enabled AC Amplifier

AC Power at 20 kHz: 900 Wrms
For High-Power Applications to: 150+ kHz

GCL

GCL

Ground Current Limiter

Active protection with red LED indicator; resettable

 

VMON20

VMON20

Voltage & Current Monitor

Convenient, scaled monitoring of voltage and current

Related Products

T 1000

T 1000

Coupling Transformer

Turns Ratio: 10-to-1 step down
Output: Up to 100 Arms

T 3700

T 3700

Coupling Transformer

Turns Ratio: 1-to-37 step up
Output: Up to 3700 Vrms

Want to discuss a product or application?

Your local AE Techron Representative can help find the right system for your needs.
We're the audio-bandwidth experts.

Find Local Rep